![]() Cartridges are also available for CeliteACT, Kaolin-ACT, PT/INR, Troponin I/cTnI, CK-MB and BNP (Table 1). Sensors for analysis of pH, PCO2, PO2, TCO2, sodium, potassium, chloride, ionized calcium, glucose, lactate, creatinine, urea nitrogen (BUN) and hematocrit are available in a variety of panel configurations. MediSense Precision PCx or PCx Plus Glucose Test Strip: 20 secondsĬartridges A single-use disposable cartridge contains microfabricated sensors, a calibrant solution, fluidics system, and a waste chamber. Other cartridges: typically 130 to 200 seconds PT/INR cartridge: to detection of end point – up to 300 seconds (5 min.)ĬTnI and BNP cartridges: 600 seconds (10 min.) (N/A at UAMS) Analysis Time ACT cartridge: to detection of end point - up to 1000 seconds (16.7 min.) A PCx Plus Glucose Test Strip is scanned and inserted into the i-STAT 1 Analyzer (Model Number 300) and a drop of whole blood is applied to the target area of the test strip. When a sample-filled i-STAT cartridge is inserted into a handheld for analysis, the handheld automatically controls all functions of the testing cycle including fluid movement within the cartridge, calibration and continuous quality monitoring. The System consists of the following primary components: Analyzers Analyzers (handhelds) can be the i-STAT Portable Clinical Analyzer or the i-STAT 1 Analyzer. ![]() SYSTEM OVERVIEW The i-STAT System incorporates comprehensive components needed to perform blood analysis at the point of care. 21-27 Daily Procedures Monthly Procedures Periodic Procedures Calibration. 13-20 Calculations Displayed Results Suppressed Results Printing and Transmitting Results Reference Ranges and Reportable Ranges Critical Results Interferences Quality Control. 6-12 Preparation for Use Procedure for Cartridge Testing Procedure for Glucose Test Strip Testing Alternative Procedure Results. 2-5 Blood Collection Equipment Blood Volume Suitable Specimens Specimen Labeling Specimen Collection and Handling Criteria for Specimen Rejection Precautions Procedure for Analysis. 1-2 Cartridges Glucose Test Strips Controls Blood Specimens. 1 Analyzers Analysis Time Cartridges Glucose Test Strips Central Data Station or Data Manager I-STAT is a registered trademark of the Abbott group of companies in various jurisdictions.Ĭontents System Overview. This Procedure Manual is not intended to replace the System Manual. The Procedure Manual is provided on CD-ROM for this purpose. This Procedure Manual should be customized for site-specific policies and procedures. ![]() This Procedure Manual is intended to be a template for the Procedure Manual required by CLIA and laboratory accreditation bodies.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |